Category: Ulvac
Ulvac
Showing all 4 results
-
EMP-07A Liquid Nitrogen Generator
Add to cart- Purpose: Designed to produce liquid nitrogen (LN₂) from ambient air.
- LN₂ Production Capacity: 8 liters per day at 60Hz; 6 liters per day at 50Hz.
- LN₂ Storage Capacity: 40 liters.
- Air Processing Capacity: 5.2 m³ per day.
- Dimensions: 600 mm (W) × 750 mm (D) × 1,628 mm (H).
- Weight: Approximately 220 kg.
- Power Supply: 100 VAC, single-phase; power consumption of approximately 1.2 kW at 50Hz and 1.4 kW at 60Hz.
- Cooling Method: Air-cooled; no external cooling water required.
- Typical Applications: Vacuum evacuation devices, LN₂ cold traps, material analyzing devices, electron microscopes, EDS (EDX) detectors, and biological cryopreservation containers.
-
GN-10i Nitrogen Gas Generator
Add to cart- Purpose: Generates nitrogen gas (N₂) with a purity of 99% (N₂ + Ar) for various industrial applications.
- N₂ Production Rate: 10 liters per minute.
- Discharge Pressure: 0.2 MPa.
- Dew Point: Below -60°C.
- Dimensions: 400 mm (W) × 460 mm (D) × 900 mm (H).
- Weight: Approximately 60 kg.
- Power Supply: 100 VAC, single-phase; power consumption of approximately 0.4 kW at both 50Hz and 60Hz.
- Cooling Method: Air-cooled; no external cooling water required.
- Typical Applications: General industrial uses requiring nitrogen gas.
-
Qulee Reactive Gas Monitor
Add to cart- Mass Range: 1 to 200 amu
- Resolution: M/ΔM = 1M (10% peak height)
- Sensitivity: 1×10⁻³ A/Pa
- Minimum Detectable Partial Pressure: 1×10⁻¹⁰ Pa
- Ion Source: Closed ion source with magnetic field
- Emission Current: 10 μA
- Bakeout Temperature: Maximum 120°C
- Pressure Range: 1×10⁻⁶ to 13 kPa
- Pumping System: Turbo molecular pump (67 L/s for N₂)
- Power Supply: AC 100V, 15A
- Weight: 57 kg (pumping system), 38 kg (controller)
-
VPC-061 Vacuum Coater
Add to cartVPC-061 Vacuum Coater
- Ultimate Pressure: 1.3 × 10⁻³ Pa, 6.6 × 10⁻⁴ Pa (LN₂)
- Evacuation Time: 4.0 × 10⁻³ Pa/20min, 1.3 × 10⁻³ Pa/20min (LN₂)
- Bell Jar Size: Glass belljar (dia. 150mm × 200mm(H))
- Substrate Electrode Distance: Max 100mm
- Evaporation Electrode Structure: 1 point
- Recommended Substrate Size (Maximum Substrate Size): sq.25mm (sq.50mm)
- Evaporation Power Supply: 0–10V 50A (Max)
- Main Pump: Oil diffusion pump (air cooling) 50 L/sec
- Backing Pump: Oil rotary vacuum pump 20 L/min
- Liquid Nitrogen Trap: Equipped
- Automatic Leak Valve: –
- Control System: Manual control
- Weight (Body): 38kg
- Weight (Power Supply): 40kg
- Overall Dimensions (Body): 434mm(W) × 422mm(D) × 673mm(H)
- Overall Dimensions (Power Supply): 480mm(W) × 435.3mm(D) × 149mm(H)
- Power Requirement (Body): Single phase, 50/60Hz, 100V, 0.63kVA
- Power Supply: Single phase, 50/60Hz, 100V, 0.63kVA