Only logged in customers who have purchased this product may leave a review.
“Inficon – BPG400” has been added to your cart. View cart
Inficon – BAG05x
$0.00
Advantages
- Long standing, reliable and proven gauge head design
- Drop-in replacement for most nude hot ion gauge heads
- Wide range of emission currents (100 μA to 10 mA)
- Available with single/dual yttrium oxide coated iridium and dual tungsten filament cathode assemblies
- Degas: all models can be degassed using in electron bombardment (EB), BAG051, BAG052 and BAG053 can also be degassed using resistive degas (I2R)
Typical applications
- Industrial or R&D applications requiring precise vacuum measurement in the high/ultra-high vacuum range and high temperature bake-out
Related products
-
Inficon – PGE500 DeviceNet
$0.00Add to cartAdvantages
- Convection Enhanced Pirani Technology for wide measurement range and higher accuracy near atmosphere
- All-in-One active gauge with built-in display, 2 set points, and digital DeviceNet interface
- Bright digital OLED display with keypad for simple setup, calibration and operation
- Factory pre-set display units for measure or selectable via keypad
- User programmable set point relays (factory pre-set on request for volume orders)
- Gold plated tungsten filament or platinum filament for corrosive applications
- Mechanical strength, highly robust and less susceptible to mechanical shock and vibration
- Field replaceable spare sensor units
- Choice of flange options
- Compliance & standards: CE, RoHS
- Direct drop-in plug-compatible replacement for the DeviceNet versions of MKS / Granville-Phillips® Mini-Convectron® (GP275 Modules) Granville-Phillips® and Mini-Convectron® are registered trademarks of MKS Instruments, Andover, MA
Typical applications
- Fore vacuum pressure measurement
- General vacuum measurement and control form low to the high vacuum range
-
Inficon – Trigon BPG552
$0.00Add to cartAdvantages
- Dual Gauge (2 sensing elements) for a wide measurement range, cost reduction & space savings
- 2 filaments for Bayard-Alpert system
- Pirani interlock protection to avoid premature filament burnout
- Automatic high vacuum Pirani adjustment reduces operator interventions
- Galvanic isolated electronics to avoid electric stray current
- Sliding emission mode to avoid pressure jumps and freeze when switching the emission stream
- Extended bakeability due to removable calibration data chips
- Set point relays
- Bright & big OLED display (90° rotatable) with user interface
- Analog output, RS232C serial interface, EtherCAT®
- Usable in conjunction with VGC50x Controller series
- Backwards compatible to BPG402
- RoHS compliance
Typical applications
- Pressure measurement in Semiconductor processes
- Industrial coating
- General vacuum measurement and control on systems in the low to ultra high vacuum range
-
Inficon – BCG450
$0.00Add to cartAdvantages
- BCG450 saves cost and tool space and reduces the complexity of vacuum measurement installation and setup
- Gas-type-independent pressure measurement above 10 Torr provides more reliable loadlock control for any gas mixture
- Pirani interlock protects the hot filament from premature burnout
- Automatic high vacuum Pirani adjustment reduces operator interventions
- Differential pressure measurement at atmosphere eliminates uncertainty related to atmospheric pressure changes
- Easy-to-exchange sensing element with on-board calibration data guarantees reproducibility
- Optional graphic display and Fieldbus interfaces available
- RoHS compliance
Typical applications
- Pressure measurement in Semiconductor process, transfer and loadlock chambers
- Industrial coating
- General vacuum measurement and control on systems in the low to ultra high vacuum range
-
Inficon – PGE500 RS485/ Analog
$0.00Add to cartAdvantages
- Convection Enhanced Pirani Technology for wide measurement range and higher accuracy near atmosphere
- All-in-One active gauge with built-in display, 2 set points, 4 analog output signals, and 2 digital interfaces
- Bright digital OLED display with keypad for simple setup, calibration and operation
- 4 optional analog output signals (3 user selectable, 1 Default)
- Factory pre-set analog output signal or selectable via keypad
- Factory pre-set display units or selectable via keypad
- User programmable set point relays (factory pre-set on request for volume orders)
- Gold plated tungsten filament
- Mechanical strength, highly robust and less susceptible to mechanical shock and vibration
- Choice of flange options
- Compliance & standards: CE, RoHS
- Direct drop in replaces most Granville-Phillips® Mini-Convectron® modules (GP275) (Granville-Phillips® and Mini-Convectron® are registered trademarks of MKS Instruments, Andover, MA)
Typical applications
- Fore vacuum pressure measurement
- General vacuum measurement and control form low to the high vacuum range
-
Inficon – Porter CDG020D
$0.00Add to cartBenefits
- Excellent span stability – gas type independent
- Alumina sensor
- Compact, smallest size in it’s class
- Easy integration, any mounting orientation
- Digital signal processing
- Maintenance free
Typical applications
- Vacuum coating
- Vacuum monitoring
- Sterilization
- Food & packaging
- Vacuum oven, puller
- Analytical
- Chemical vacuum processes
Reviews