Inficon – Edge CDG045D2
Advantages
- Compact, saves valuable tool space
- Easy integration, EtherCAT, wide variety of full scales and flanges, standard with two set points
- Easy one push button or remote signal zero command, zero offset adjustable
- Diagnostic port for quick service and maintenance
- Two year warranty, longer life time with advanced heating concept and gauge protection
- No long term recalibration due to excellent signal stability and repeatability, even in harsh plasma applications
- Compliance & standards: CE, EN, UL, SEMI, RoHS
Typical applications
CVD, Etch, PVD and other semiconductor production processes
Related products
-
Inficon – PBR 260
Add to cartAdvantages
- PBR 260 Pirani/Bayard-Alpert hot cathode combination gauge offers general vacuum measurement and control in the low to ultrahigh vacuum range with just one compact measuring device
- Flange size: DN 25 ISO-KF, DN 40 CF-R, DN 40 ISO-KF
- Maximum pressure applies to inert gases and temperatures of less then 55°C
- Highly accurate, excellent repeatability in the process range 10-8 … 10-2 mbar
- Bayard-Alpert sensor ON/OFF automatically controlled by Pirani sensor
- Long-life yttrium oxide coated iridium filament
- RoHS compliance
Drop in compatible to other manufacturers PBR 260 Pirani/Bayard-Alpert hot cathode gauges
- Part number IGG27000 matches PT R27 000
- Part number IGG27001 matches PT R27 001
- Part number IGG27002 matches PT R27 00
Typical applications
- General pressure measurement in semiconductor and analytical process environment
- Optical and other industrial coating processes
-
Inficon – BPG400
Add to cartAdvantages
- Extremely wide measurement range from 5×10-10 mbar to atmosphere (3.8×10-10 Torr to atmosphere)
- Excellent repeatability in the process pressure range from 10-8 … 10-2 mbar of 5%
- The Pirani interlock protects the Bayard-Alpert system from premature filament burnout and excess contamination from high pressure operation
- Long-life yttrium oxide coated iridium filament
- Optional graphic display and Fieldbus interfaces available
- Automatic high vacuum Pirani adjustment reduces operator interventions
- RoHS compliance
- General vacuum measurement and control in the low to ultra high vacuum range
Typical applications
- Pressure measurement in semiconductor process and transfer chambers
- Industrial coating
- General vacuum measurement and control in the low to ultra high vacuum range
-
Inficon – Gemini MxG5xx
Add to cartAdvantages
- Long lifetime in harsh environments
- Low magnetic stray field
- Reliable fast ignition
- Fastest maintenance – replaceable insert
- Compact size – easy to integrate
- Corrosion proof feed-through & sensor element
- Selectable measuring current
- 2 relay setpoints (in conjunction with MxG55x PROFINET and EtherCAT)
- PROFINET, EtherCAT and RS232/ RS485 digital interace
Typical applications
- Base pressure monitoring and control, from atmosphere to high vacuum in evaporation and sputter coating applications.
- General vacuum measurement – industrial furnaces, architectural glass, semiconductor, Refrigeration/ air conditioning and production laboratory`s
- Analytical and R&D applications – mass spectrometry, electron microscopes, ophthalmic, optical, medical and high energy physics.
-
Inficon – Trigon BAG552
Add to cartAdvantages
- Pure Bayard-Alpert measuring system for a wide UHV & HV measurement range
- 2 filaments for Bayard-Alpert system
- Galvanic isolated electronics to avoid electric stray current
- Sliding emission mode to avoid pressure jumps and freeze when switching the emission stream
- Extended bakeability due to removable calibration data chips
- Set point relays
- Bright & big OLED display (90° rotateable) with user interface
- Analog output, RS232C serial interface, EtherCAT®
- Usable in conjunction with VGC50x Controller series
- RoHS compliance
Typical applications
- Pressure measurement in Semiconductor processes
- Industrial coating
- General vacuum measurement and control on systems in the high to ultra high vacuum range
-
Inficon – PCG55x
Add to cart- Gas type independent above 10 mbar – allows safe venting with any gas mixture
- High accuracy and reproducibility at atmosphere – for reliable, fast atmospheric pressure detection
- Versatile of mounting orientation – provides engineering freedom in tool design
- Available with Tungsten (PCG550) or Nickel (PCG552) filament or with a fully ceramic coated (PCG554) sensor unit for highly corrosive applications
- Latest EtherCAT protocol Standard ETG.5003.2080 S (R) V1.3.0
- Easy to exchange plug & play sensor element with on-board calibration data – guarantees high reproducibility and low cost of ownership
- Selectable output signal for easy integration
- Optional atmospheric switch, display and digital interfaces
- Compliance & standards: CE, EN, UL, CSA, RoHS
Reviews
There are no reviews yet.