Only logged in customers who have purchased this product may leave a review.
Inficon – Edge CDG045D2
Advantages
- Compact, saves valuable tool space
- Easy integration, EtherCAT, wide variety of full scales and flanges, standard with two set points
- Easy one push button or remote signal zero command, zero offset adjustable
- Diagnostic port for quick service and maintenance
- Two year warranty, longer life time with advanced heating concept and gauge protection
- No long term recalibration due to excellent signal stability and repeatability, even in harsh plasma applications
- Compliance & standards: CE, EN, UL, SEMI, RoHS
Typical applications
CVD, Etch, PVD and other semiconductor production processes
Related products
-
Inficon – PBR 260
Add to cartAdvantages
- PBR 260 Pirani/Bayard-Alpert hot cathode combination gauge offers general vacuum measurement and control in the low to ultrahigh vacuum range with just one compact measuring device
- Flange size: DN 25 ISO-KF, DN 40 CF-R, DN 40 ISO-KF
- Maximum pressure applies to inert gases and temperatures of less then 55°C
- Highly accurate, excellent repeatability in the process range 10-8 … 10-2 mbar
- Bayard-Alpert sensor ON/OFF automatically controlled by Pirani sensor
- Long-life yttrium oxide coated iridium filament
- RoHS compliance
Drop in compatible to other manufacturers PBR 260 Pirani/Bayard-Alpert hot cathode gauges
- Part number IGG27000 matches PT R27 000
- Part number IGG27001 matches PT R27 001
- Part number IGG27002 matches PT R27 00
Typical applications
- General pressure measurement in semiconductor and analytical process environment
- Optical and other industrial coating processes
-
Inficon – MAG470
Add to cartAdvantages
- No filament to burn out
- Extended version, sensor bakeout up to 250°C
- Excellent ignition properties
- Easy to clean
- Metal-sealed feedthrough
- LED indicator for high voltage on
- Logarithmic analog output signal
Typical applications
- Ultra high vacuum pressure monitoring
- Base pressure for evaporation and sputtering systems
- General vacuum measurement and control in the medium and high vacuum range
-
Inficon – Trigon BCG552
Add to cartAdvantages
- 3 + 1 sensing elements for extremely wide measurement range, cost reduction & space savings
- 2 filaments for Bayard-Alpert system
- Gas type independent pressure measurement above 10 Torr provides more reliable load lock control for any gas mixtures
- Differential pressure measurement eliminates uncertainty related to atmospheric pressure changes
- Automatic high vacuum Pirani adjustment reduces operator interventions
- Galvanic isolated electronics to avoid electric stray current
- Sliding emission mode to avoid pressure jumps and freeze when switching the emission stream
- Set point relays
- Bright & big OLED display (90° rotatable) with user interface
- Analog output, RS232C serial interface, EtherCAT®
- Usable in conjunction with VGC50x Controller series
- Backwards compatible to TripleGauge® BCG450
- RoHS compliance
Typical applications
- Pressure measurement in Semiconductor processes, transfer and loadlock chambers
- Industrial coating
- General vacuum measurement and control on systems in the low to ultra high vacuum range
-
Inficon – Trigon BPG552
Add to cartAdvantages
- Dual Gauge (2 sensing elements) for a wide measurement range, cost reduction & space savings
- 2 filaments for Bayard-Alpert system
- Pirani interlock protection to avoid premature filament burnout
- Automatic high vacuum Pirani adjustment reduces operator interventions
- Galvanic isolated electronics to avoid electric stray current
- Sliding emission mode to avoid pressure jumps and freeze when switching the emission stream
- Extended bakeability due to removable calibration data chips
- Set point relays
- Bright & big OLED display (90° rotatable) with user interface
- Analog output, RS232C serial interface, EtherCAT®
- Usable in conjunction with VGC50x Controller series
- Backwards compatible to BPG402
- RoHS compliance
Typical applications
- Pressure measurement in Semiconductor processes
- Industrial coating
- General vacuum measurement and control on systems in the low to ultra high vacuum range
-
Inficon – BCG450
Add to cartAdvantages
- BCG450 saves cost and tool space and reduces the complexity of vacuum measurement installation and setup
- Gas-type-independent pressure measurement above 10 Torr provides more reliable loadlock control for any gas mixture
- Pirani interlock protects the hot filament from premature burnout
- Automatic high vacuum Pirani adjustment reduces operator interventions
- Differential pressure measurement at atmosphere eliminates uncertainty related to atmospheric pressure changes
- Easy-to-exchange sensing element with on-board calibration data guarantees reproducibility
- Optional graphic display and Fieldbus interfaces available
- RoHS compliance
Typical applications
- Pressure measurement in Semiconductor process, transfer and loadlock chambers
- Industrial coating
- General vacuum measurement and control on systems in the low to ultra high vacuum range
Reviews
There are no reviews yet.