Only logged in customers who have purchased this product may leave a review.
Inficon – MAG470
Advantages
- No filament to burn out
- Extended version, sensor bakeout up to 250°C
- Excellent ignition properties
- Easy to clean
- Metal-sealed feedthrough
- LED indicator for high voltage on
- Logarithmic analog output signal
Typical applications
- Ultra high vacuum pressure monitoring
- Base pressure for evaporation and sputtering systems
- General vacuum measurement and control in the medium and high vacuum range
Related products
-
Inficon – PBR 260
Add to cartAdvantages
- PBR 260 Pirani/Bayard-Alpert hot cathode combination gauge offers general vacuum measurement and control in the low to ultrahigh vacuum range with just one compact measuring device
- Flange size: DN 25 ISO-KF, DN 40 CF-R, DN 40 ISO-KF
- Maximum pressure applies to inert gases and temperatures of less then 55°C
- Highly accurate, excellent repeatability in the process range 10-8 … 10-2 mbar
- Bayard-Alpert sensor ON/OFF automatically controlled by Pirani sensor
- Long-life yttrium oxide coated iridium filament
- RoHS compliance
Drop in compatible to other manufacturers PBR 260 Pirani/Bayard-Alpert hot cathode gauges
- Part number IGG27000 matches PT R27 000
- Part number IGG27001 matches PT R27 001
- Part number IGG27002 matches PT R27 00
Typical applications
- General pressure measurement in semiconductor and analytical process environment
- Optical and other industrial coating processes
-
Inficon – Gemini MxG5xx
Add to cartAdvantages
- Long lifetime in harsh environments
- Low magnetic stray field
- Reliable fast ignition
- Fastest maintenance – replaceable insert
- Compact size – easy to integrate
- Corrosion proof feed-through & sensor element
- Selectable measuring current
- 2 relay setpoints (in conjunction with MxG55x PROFINET and EtherCAT)
- PROFINET, EtherCAT and RS232/ RS485 digital interace
Typical applications
- Base pressure monitoring and control, from atmosphere to high vacuum in evaporation and sputter coating applications.
- General vacuum measurement – industrial furnaces, architectural glass, semiconductor, Refrigeration/ air conditioning and production laboratory`s
- Analytical and R&D applications – mass spectrometry, electron microscopes, ophthalmic, optical, medical and high energy physics.
-
Inficon – PGE500 RS485/ Analog
Add to cartAdvantages
- Convection Enhanced Pirani Technology for wide measurement range and higher accuracy near atmosphere
- All-in-One active gauge with built-in display, 2 set points, 4 analog output signals, and 2 digital interfaces
- Bright digital OLED display with keypad for simple setup, calibration and operation
- 4 optional analog output signals (3 user selectable, 1 Default)
- Factory pre-set analog output signal or selectable via keypad
- Factory pre-set display units or selectable via keypad
- User programmable set point relays (factory pre-set on request for volume orders)
- Gold plated tungsten filament
- Mechanical strength, highly robust and less susceptible to mechanical shock and vibration
- Choice of flange options
- Compliance & standards: CE, RoHS
- Direct drop in replaces most Granville-Phillips® Mini-Convectron® modules (GP275) (Granville-Phillips® and Mini-Convectron® are registered trademarks of MKS Instruments, Andover, MA)
Typical applications
- Fore vacuum pressure measurement
- General vacuum measurement and control form low to the high vacuum range
-
Inficon – PSG55x
Add to cartAdvantages
- Available with Tungsten (PSG550) or Nickel (PSG552) filament or with a fully ceramic coated (PSG554) sensor unit for highly corrosive applications
- Optional display, setpoints and digital interfaces
- Latest EtherCAT protocol Standard ETG.5003.2080 S (R) V1.3.0
- Easy to exchange plug & play sensor element with on-board calibration data – guarantees high reproducibility and low cost of ownership
- Selectable output signal and various plug versions for easy integration
- Mounts in any orientation – provides engineering freedom in tool design
- Diagnostic port on all versions
- Compliance & standards: CE, EN, UL, CSA, RoHS
Typical applications
- Â Fore vacuum pressure measurement
- Â Safety circuits in vacuum systems
- Â General vacuum measurement and control from low to the high vacuum range
-
Inficon – Trigon BAG552
Add to cartAdvantages
- Pure Bayard-Alpert measuring system for a wide UHV & HV measurement range
- 2 filaments for Bayard-Alpert system
- Galvanic isolated electronics to avoid electric stray current
- Sliding emission mode to avoid pressure jumps and freeze when switching the emission stream
- Extended bakeability due to removable calibration data chips
- Set point relays
- Bright & big OLED display (90° rotateable) with user interface
- Analog output, RS232C serial interface, EtherCAT®
- Usable in conjunction with VGC50x Controller series
- RoHS compliance
Typical applications
- Pressure measurement in Semiconductor processes
- Industrial coating
- General vacuum measurement and control on systems in the high to ultra high vacuum range
Reviews