Only logged in customers who have purchased this product may leave a review.
“Inficon – BPG402-Sx” has been added to your cart. View cart
Inficon – Spot CDS530D
$0.00
Advantages
- The dual miniature sensor offers a high accuracy in a wide measurement range
- Wide range, high precision
- Excellent repeatability and long-term stability
- Sensor electronics with SPI interface for easy integration
- Welded custom flange for integration of calibrated sensor
- Fast response time
Related products
-
Inficon – PSG55x
$0.00Add to cartAdvantages
- Available with Tungsten (PSG550) or Nickel (PSG552) filament or with a fully ceramic coated (PSG554) sensor unit for highly corrosive applications
- Optional display, setpoints and digital interfaces
- Latest EtherCAT protocol Standard ETG.5003.2080 S (R) V1.3.0
- Easy to exchange plug & play sensor element with on-board calibration data – guarantees high reproducibility and low cost of ownership
- Selectable output signal and various plug versions for easy integration
- Mounts in any orientation – provides engineering freedom in tool design
- Diagnostic port on all versions
- Compliance & standards: CE, EN, UL, CSA, RoHS
Typical applications
- Fore vacuum pressure measurement
- Safety circuits in vacuum systems
- General vacuum measurement and control from low to the high vacuum range
-
Inficon – BPG402-Sx
$0.00Add to cartAdvantages
- Extremely wide measurement range from 5×10-10 mbar to atmosphere (3.8×10-10 Torr to atmosphere)
- Excellent repeatability in the process pressure range from 10-8 … 10-2 mbar of 5%
- Pirani interlock protects the filament from premature burnout
- Two long-life yttrium oxide coated iridium filaments
- Optional graphic display and Fieldbus interfaces available
- Automatic high vacuum Pirani adjustment reduces operator interventions
- Easy to exchange sensing element with on-board calibration data guarantees high reproducibility
- RoHS compliance
Typical applications
- Pressure measurement in semiconductor process and transfer chambers
- Industrial coating
- General vacuum measurement and control in the low to ultra high vacuum range
-
Inficon – PGE500 RS485/ Analog
$0.00Add to cartAdvantages
- Convection Enhanced Pirani Technology for wide measurement range and higher accuracy near atmosphere
- All-in-One active gauge with built-in display, 2 set points, 4 analog output signals, and 2 digital interfaces
- Bright digital OLED display with keypad for simple setup, calibration and operation
- 4 optional analog output signals (3 user selectable, 1 Default)
- Factory pre-set analog output signal or selectable via keypad
- Factory pre-set display units or selectable via keypad
- User programmable set point relays (factory pre-set on request for volume orders)
- Gold plated tungsten filament
- Mechanical strength, highly robust and less susceptible to mechanical shock and vibration
- Choice of flange options
- Compliance & standards: CE, RoHS
- Direct drop in replaces most Granville-Phillips® Mini-Convectron® modules (GP275) (Granville-Phillips® and Mini-Convectron® are registered trademarks of MKS Instruments, Andover, MA)
Typical applications
- Fore vacuum pressure measurement
- General vacuum measurement and control form low to the high vacuum range
-
Inficon – PGE300
$0.00Add to cartAdvantages
- Convection Enhanced Pirani Technology for wide measurement range and higher accuracy near atmosphere
- All-in-One active gauge with built-in display, 1 set point and 3 selectable analog output signals
- Bright digital LED display features a user friendly for calibration and operation
- 3 optional analog output signals (user selectable)
- Factory pre-set analog output signal or selectable via user interface
- Factory pre-set display units or selectable via user interface
- User programmable set point relays
- Gold plated tungsten filament
- Mechanical strength, highly robust and less susceptible to mechanical shock and vibration
- Choice of flange options
- Compliance & standards: CE, RoHS
- Direct drop in replaces most Granville-Phillips® Mini-Convectron® modules (GP275) and ideal device forupgrading your installed thermocouple gauges (Granville-Phillips® and Mini-Convectron® are registered trademarks of MKS Instruments, Andover, MA)
Typical applications
- Fore vacuum pressure measurement
- General vacuum measurement and control from low to the high vacuum range
-
Inficon – PPG570
$0.00Add to cartAdvantages
- Gas type independent above 2 mbar – allows safe venting with any gas mixture
- High accuracy and reproducibility at atmosphere – for reliable, fast atmospheric pressure detection
- Atmospheric ambient pressure measurement
- Up to 3 solid state relays
- Versatile of mounting orientation – provides engineering freedom in tool design
- Selectable analog output signal for easy system integration
- Digital interfaces RS232/ RS485
- Able to direct drop in replace MKS901P “MicroPirani™ – and Piezo Loadlock Vacuum Pressure Transducer”.
- Compliance & standards: CE, EN, UL, CSA, RoHS
Typical applications
- Semiconductor load-lock applications
- Use in Analytical equipment/ mass sepctrometers
- Physical vapor deposition
- Physical vapor deposition
Reviews