Showing 17–32 of 57 results

  • Inficon – IRG080

    Advantages

    • Developed for applications requiring high measurement accuracy in the high and ultra-high vacuum range
    • Electrode system configuration according to ISO TS 6737
    • True pressure for all gas species thanks to predictable relative gas sensitivity with small uncertainty
    • Stable electron emission and lack of influence from ESD or X-ray effects
    • Reproducible and easy to transport
    • Bakeable to 165 °C (with temperature resistant cable) or up to 400 °C without connector unit
    • Mu-metal intermediate piece available for magnetic shielding purposes
    Add to cart
  • Inficon – MAG050, MAG060, MAG070

    Advantages

    • Reliable and proven gauge head design, based on the inverted magnetron principle
    • Large vacuum pressure measurement range capability from 1×10-11 (MAG070) to 5×10-3  mbar
    • Bakeable to 150 °C (MAG050) or 250 °C (MAG060, MAG070)
    • Good ignition properties
    • Corrosion resistant with ceramic feedthrough
    • Radiation resistant design available (MAG060, MAG070)
    • Easy to maintain, low cost of ownership

    Typical applications

    • General vacuum measurement and control for demanding and/or high temperature applications from low to the high vacuum range

     

    Add to cart
  • Inficon – MAG084

    Advantages

    • Developed to sustain operation in strong external magnetic fields
    • Reliable and proven gauge head design, based on the inverted magnetron principle
    • Innovative double ionization chamber principle
    • Bakeable to 230 °C
    • Good ignition properties
    • Corrosion resistant with ceramic feedthrough
    • Radiation resistant design to 1×107 Gy
    • Easy to maintain, low cost of ownership

    Typical applications

    • Special Fusion and R&D applications presenting strong external magnetic fields
    Add to cart
  • Inficon – MAG470

    Advantages

    • No filament to burn out
    • Extended version, sensor bakeout up to 250°C
    • Excellent ignition properties
    • Easy to clean
    • Metal-sealed feedthrough
    • LED indicator for high voltage on
    • Logarithmic analog output signal

    Typical applications

    • Ultra high vacuum pressure monitoring
    • Base pressure for evaporation and sputtering systems
    • General vacuum measurement and control in the medium and high vacuum range
    Add to cart
  • Inficon – MPG40X

    Advantages

    • Combination gauge – Inverted Magnetron & Pirani
    • Wide measurement range from 5 x 10-9 mbar to atmosphere
    • No filament to burn out
    • Excellent ignition properties
    • Easy to clean
    • FPM or metal-sealed feedthrough
    • LED indicator for high voltage on
    • Logarithmic analog output signal

    Typical applications

    • High vacuum pressure monitoring
    • Base pressure for evaporation and sputtering systems
    • General vacuum measurement and control in the medium and high vacuum range
    Add to cart
  • Inficon – PBR 260

    Advantages

    • PBR 260 Pirani/Bayard-Alpert hot cathode combination gauge offers general vacuum measurement and control in the low to ultrahigh vacuum range with just one compact measuring device
    • Flange size: DN 25 ISO-KF, DN 40 CF-R, DN 40 ISO-KF
    • Maximum pressure applies to inert gases and temperatures of less then 55°C
    • Highly accurate, excellent repeatability in the process range 10-8 … 10-2 mbar
    • Bayard-Alpert sensor ON/OFF automatically controlled by Pirani sensor
    • Long-life yttrium oxide coated iridium filament
    • RoHS compliance

    Drop in compatible to other manufacturers PBR 260 Pirani/Bayard-Alpert hot cathode gauges

    • Part number IGG27000 matches PT R27 000
    • Part number IGG27001 matches PT R27 001
    • Part number IGG27002 matches PT R27 00

    Typical applications

    • General pressure measurement in semiconductor and analytical process environment
    • Optical and other industrial coating processes
    Add to cart
  • Inficon – PCG55x

    • Gas type independent above 10 mbar – allows safe venting with any gas mixture
    • High accuracy and reproducibility at atmosphere – for reliable, fast atmospheric pressure detection
    • Versatile of mounting orientation – provides engineering freedom in tool design
    • Available with Tungsten (PCG550) or Nickel (PCG552) filament or with a fully ceramic coated (PCG554) sensor unit for highly corrosive applications
    • Latest EtherCAT protocol Standard ETG.5003.2080 S (R) V1.3.0
    • Easy to exchange plug & play sensor element with on-board calibration data – guarantees high reproducibility and low cost of ownership
    • Selectable output signal for easy integration
    • Optional atmospheric switch, display and digital interfaces
    • Compliance & standards: CE, EN, UL, CSA, RoHS
    Add to cart
  • Inficon – PGD500

    Advantages

    • User selectable measurement unit (Pa, mbar or Torr)
    • Compact bench top model design can be easily mounted in a panel or 19″ rack
    • 0 to 10 V output signal from the gauge is available for use in PLC or with a chart recorder
    • One free adjustable set point
    • CE certified

    Typical Applications

    • Fore vacuum pressure measurement
    • Pressure measurement on evacuation/filling stations for RAC applications
    • Pressure measurement in light bulb production lines
    • General vacuum measurement and control in the medium and rough vacuum range
    Add to cart
  • Inficon – PGE050

    Advantages

    • Convection enhanced Pirani technology for wide measurement range and higher accuracy near atmosphere
    • Gold plated tungsten filament
    • Mechanical robust and less susceptible to mechanical shock and vibration
    • Large choice of flange options
    • Compliance & standards: CE, RoHS
    • Direct drop in replaces Granville-Phillips® Convectron® gauge sensor (same plug/ pinouts)
    • PGE050 accepts Granville-Phillips® Convectron® controllers, cables and modules
    • Ideal gauge sensor for upgrading your installed Pirani and thermocouple gauge

    Typical applications

    • General vacuum measurement and control from atmosphere to high vacuum range
    Add to cart
  • Inficon – PGE300

    Advantages

    • Convection Enhanced Pirani Technology for wide measurement range and higher accuracy near atmosphere
    • All-in-One active gauge with built-in display, 1 set point and 3 selectable analog output signals
    • Bright digital LED display features a user friendly for calibration and operation
    • 3 optional analog output signals (user selectable)
    • Factory pre-set analog output signal or selectable via user interface
    • Factory pre-set display units or selectable via user interface
    • User programmable set point relays
    • Gold plated tungsten filament
    • Mechanical strength, highly robust and less susceptible to mechanical shock and vibration
    • Choice of flange options
    • Compliance & standards: CE, RoHS
    • Direct drop in replaces most Granville-Phillips® Mini-Convectron® modules (GP275) and ideal device forupgrading your installed thermocouple gauges (Granville-Phillips® and Mini-Convectron® are registered trademarks of MKS Instruments, Andover, MA)

    Typical applications

    • Fore vacuum pressure measurement
    • General vacuum measurement and control from low to the high vacuum range
    Add to cart
  • Inficon – PGE500 DeviceNet

    Advantages

    • Convection Enhanced Pirani Technology for wide measurement range and higher accuracy near atmosphere
    • All-in-One active gauge with built-in display, 2 set points, and digital DeviceNet interface
    • Bright digital OLED display with keypad for simple setup, calibration and operation
    • Factory pre-set display units for measure or selectable via keypad
    • User programmable set point relays (factory pre-set on request for volume orders)
    • Gold plated tungsten filament or platinum filament for corrosive applications
    • Mechanical strength, highly robust and less susceptible to mechanical shock and vibration
    • Field replaceable spare sensor units
    • Choice of flange options
    • Compliance & standards: CE, RoHS
    • Direct drop-in plug-compatible replacement for the DeviceNet versions of MKS / Granville-Phillips® Mini-Convectron® (GP275 Modules) Granville-Phillips® and Mini-Convectron® are registered trademarks of MKS Instruments, Andover, MA

    Typical applications

    • Fore vacuum pressure measurement
    • General vacuum measurement and control form low to the high vacuum range
    Add to cart
  • Inficon – PGE500 RS485/ Analog

    Advantages

    • Convection Enhanced Pirani Technology for wide measurement range and higher accuracy near atmosphere
    • All-in-One active gauge with built-in display, 2 set points, 4 analog output signals, and 2 digital interfaces
    • Bright digital OLED display with keypad for simple setup, calibration and operation
    • 4 optional analog output signals (3 user selectable, 1 Default)
    • Factory pre-set analog output signal or selectable via keypad
    • Factory pre-set display units or selectable via keypad
    • User programmable set point relays (factory pre-set on request for volume orders)
    • Gold plated tungsten filament
    • Mechanical strength, highly robust and less susceptible to mechanical shock and vibration
    • Choice of flange options
    • Compliance & standards: CE, RoHS
    • Direct drop in replaces most Granville-Phillips® Mini-Convectron® modules (GP275) (Granville-Phillips® and Mini-Convectron® are registered trademarks of MKS Instruments, Andover, MA)

    Typical applications

    • Fore vacuum pressure measurement
    • General vacuum measurement and control form low to the high vacuum range
    Add to cart
  • Inficon – Porter CDG020D

    Benefits

    • Excellent span stability – gas type independent
    • Alumina sensor
    • Compact, smallest size in it’s class
    • Easy integration, any mounting orientation
    • Digital signal processing
    • Maintenance free

    Typical applications

    • Vacuum coating
    • Vacuum monitoring
    • Sterilization
    • Food & packaging
    • Vacuum oven, puller
    • Analytical
    • Chemical vacuum processes
    Add to cart
  • Inficon – PPG550

    Advantages

    • Gas type independent above 2 mbar – allows safe venting with any gas mixture
    • High accuracy and reproducibility at atmosphere – for reliable, fast atmospheric pressure detection
    • Versatile of mounting orientation – provides engineering freedom in tool design
    •  Selectable analog output signal for easy system integration
    •  Digital interfaces RS232/ RS485
    • Compliance & standards: CE, EN, UL, CSA, RoHS
    • Able to direct drop in replace MKS910 “DualTrans™ MicroPirani™ – Absolute Piezo Vacuum Pressure Transducers” as well as MKS925  “Micro Pirani™ Vacuum Pressure Transducers”. DualTrans™ MicroPirani™ are registered trademarks of MKS Instruments, Andover, MA
    • Compliance & standards: CE, EN, UL, CSA, RoHS

    Typical applications

    • Use in Analytical equipment/ mass spectrometers
    • Physical vapor deposition
    • Fore-line measurement
    •  Gas-backfilling
    Add to cart
  • Inficon – PPG570

    Advantages

    • Gas type independent above 2 mbar – allows safe venting with any gas mixture
    • High accuracy and reproducibility at atmosphere – for reliable, fast atmospheric pressure detection
    •  Atmospheric ambient pressure measurement
    • Up to 3 solid state relays
    • Versatile of mounting orientation – provides engineering freedom in tool design
    •  Selectable analog output signal for easy system integration
    • Digital interfaces RS232/ RS485
    • Able to direct drop in replace MKS901P “MicroPirani™ – and Piezo Loadlock Vacuum Pressure Transducer”.
    • Compliance & standards: CE, EN, UL, CSA, RoHS

    Typical applications

    • Semiconductor load-lock applications
    • Use in Analytical equipment/ mass sepctrometers
    • Physical vapor deposition
    • Physical vapor deposition
    Add to cart
  • Inficon – PSG010, PSG017 & PSG018

    Advantages

    • Elastomer (PSG010) or metal-sealed (PSG017, PSG018) design
    • Specified high measurement accuracy and repeatability
    • Bake-out temperature up to 100 °C (PSG010) / 250 °C (PSG017, PSG018)
    • Ionizing radiation resistant up to 106 Gy (PSG017, PSG018)
    • Corrosion resistance with Ni filament (PSG017)
    • Cable length up to 100 m (500 m with PI 300 DL/CP 300 T11L)

    Typical applications

    • General vacuum measurement and control for demanding and/or high temperature applications from low to the high vacuum range
    Add to cart