Shop
Showing 65–80 of 173 results
-
HPB-4B
$39,800.00Select options This product has multiple variants. The options may be chosen on the product page- Individual temperature control for each device up to 600 W
- Test devices at a maximum temperature of 150°C with a liquid-cooled heat-sink per device
- Programmable clocks edges with 2-nanosecond edge resolution and 8 on-the-fly timing sets
- System capacity of 14 burn-in boards (112 devices)
- 12 vector formats per-pin per-cycle with memory testing extensions
- 19 programmable voltage regulators provide 2060 amps of device current per burn-in board
- High-speed clock programmable up to 800 MHz
- 128 I/O signals per board
- 64M vector memory, 8G scan
-
HPB-5C+
$55,000.00Add to cart- Individual temperature control for each device up to 150 W
- Variable oven overflow control
- Individual pattern zone per burn-in board slot
- 32M vector memory standard, 64M optional
- Tests devices at a temperature of up to 150°C
- Up to 800 MHz clock rate
- 128 digital I/O channels per burn-in board
- System capacity of 384 devices under test with individual temperature control per device
- 16 programmable voltage regulators with 1080 amps of device under test power per burn-in board
- 8 high-current supplies
- (0-4 volts at up to 125 amps each)
- 8 low-current supplies
- (0-6 volts at up to 10 amps each)
-
HPB-6
Add to cart- Handle devices up to 1000 watts
- 16 independent burn-in board slots
- 64M standard and 128M optional parallel vector depth –subroutine capable
- 8G scan vector depth
- 128 formatted vector I/O channels plus 128 vector output-only channels
- 8 programmable high-frequency clocks, up to 350 MHz – LVDS to the BiB
-
I-V Testing System
$8,900.00Add to cart- Standalone or integrated with the OAI I-V Measurement System
- I-V Test Systems: Standalone or fully Integrated with any OAI Solar Simulator
- Extremely accurate measurements of solar cell I-V
- Parameters & efficiency
- Propritary IV Rider Software measuring critical I-V Parameters
- Standard ranges of I-V testers are: S1a, 1-5A, and 20A – verified at Fraunhofer, ISE, & NREL.
- Multiplexing function to test various solar cells
- Measures up to +/- 35A/ +/-10V/350w I-V RANGE
- Features corrected I-V curves & Graphical/ Tabular QC monitoring
- Optional Normalization Kit to correct any lamp instability
-
Inficon – Augent OPG550
Add to cartAdvantages
- High speed leak detection allows chamber leak test
- Increase of productivity and yield
- Long life time, no filament burns, air inrush protection
- Withstand process chemistry
- Smart algorithm for easy integration
- Compact design and small footprint
- Reliable and fast start up
Typical Applications
- Chamber leak check, faster RoR (rate of rise) test
- Leak check to find internal leaks from gas supply lines
- Real time end point control
- Gas type and concentrations control
-
Inficon – BAG05x
Add to cartAdvantages
- Long standing, reliable and proven gauge head design
- Drop-in replacement for most nude hot ion gauge heads
- Wide range of emission currents (100 μA to 10 mA)
- Available with single/dual yttrium oxide coated iridium and dual tungsten filament cathode assemblies
- Degas: all models can be degassed using in electron bombardment (EB), BAG051, BAG052 and BAG053 can also be degassed using resistive degas (I2R)
Typical applications
- Industrial or R&D applications requiring precise vacuum measurement in the high/ultra-high vacuum range and high temperature bake-out
-
Inficon – BAG302
Add to cartAdvantages
- Wide measurement range from 1.3 × 10-9 to 6.7×10-2 mbar(1 × 10-9 to 5 × 10-2 Torr)
- Two standard long-life yttrium oxide coated iridium filaments
- All-in-One active gauge with built-in display, set-point, analog output and standard integrated RS485 digital interface
- Bright digital OLED display with keypad for simple setup, operation and programming
- User programmable set point relay
- User programmable display units in mbar, Torr or Pa
- User selectable Auto-ranging of emission current
- Mechanical strength and ruggedness
- Choice of various flange options
- Easy to exchange sensing element
- Compliance & standards: CE, RoHS
- Direct drop in replaces Granville-Phillips® 354 Micro-Ion® Module – identical control functions including softwarecommands (RS485) (Granville-Phillips® and Micro-Ion® are registered trademarks of MKS Instruments, Andover, MA)
Typical applications
- Pressure measurement in semiconductor process and transfer chambers
- Industrial coating
- General vacuum measurement and control in the low to ultra high vacuum range
-
Inficon – BAG402
Add to cartAdvantages
- Measurement range from 5×10-10 mbar to 2.7×10-2 mbar (3.75×10-10 Torr to 5×10-2 Torr)
- Excellent repeatability in the process pressure range from 10-8 … 10-2 mbar of 5%
- Overpressure detection protects the filament from premature burnout
- Two long-life yttrium oxide coated iridium filaments
- Automatic emission current selection reduces control complexity
- Easy to exchange sensing element with on-board calibration data guarantees high reproducibility
- RoHS compliance
Typical applications
- Pressure measurement in semiconductor process and transfer chambers
- Industrial coating
- General vacuum measurement and control in the low to ultra high vacuum range
-
Inficon – BCG450
Add to cartAdvantages
- BCG450 saves cost and tool space and reduces the complexity of vacuum measurement installation and setup
- Gas-type-independent pressure measurement above 10 Torr provides more reliable loadlock control for any gas mixture
- Pirani interlock protects the hot filament from premature burnout
- Automatic high vacuum Pirani adjustment reduces operator interventions
- Differential pressure measurement at atmosphere eliminates uncertainty related to atmospheric pressure changes
- Easy-to-exchange sensing element with on-board calibration data guarantees reproducibility
- Optional graphic display and Fieldbus interfaces available
- RoHS compliance
Typical applications
- Pressure measurement in Semiconductor process, transfer and loadlock chambers
- Industrial coating
- General vacuum measurement and control on systems in the low to ultra high vacuum range
-
Inficon – BPG400
Add to cartAdvantages
- Extremely wide measurement range from 5×10-10 mbar to atmosphere (3.8×10-10 Torr to atmosphere)
- Excellent repeatability in the process pressure range from 10-8 … 10-2 mbar of 5%
- The Pirani interlock protects the Bayard-Alpert system from premature filament burnout and excess contamination from high pressure operation
- Long-life yttrium oxide coated iridium filament
- Optional graphic display and Fieldbus interfaces available
- Automatic high vacuum Pirani adjustment reduces operator interventions
- RoHS compliance
- General vacuum measurement and control in the low to ultra high vacuum range
Typical applications
- Pressure measurement in semiconductor process and transfer chambers
- Industrial coating
- General vacuum measurement and control in the low to ultra high vacuum range
-
Inficon – BPG402-Sx
Add to cartAdvantages
- Extremely wide measurement range from 5×10-10 mbar to atmosphere (3.8×10-10 Torr to atmosphere)
- Excellent repeatability in the process pressure range from 10-8 … 10-2 mbar of 5%
- Pirani interlock protects the filament from premature burnout
- Two long-life yttrium oxide coated iridium filaments
- Optional graphic display and Fieldbus interfaces available
- Automatic high vacuum Pirani adjustment reduces operator interventions
- Easy to exchange sensing element with on-board calibration data guarantees high reproducibility
- RoHS compliance
Typical applications
- Pressure measurement in semiconductor process and transfer chambers
- Industrial coating
- General vacuum measurement and control in the low to ultra high vacuum range
-
Inficon – Cube CDGsci
Add to cartAdvantages
- True high precision pressure measurement – Ceramic technology
- Full stable output – Proven by PTB
- Flexible communication – Various modern interfaces
- All functions integrated – No controller required
- Direct mounting to chamber – Optimized center of gravity
- Transportation without isolation valve possible
Typical applications
- Transfer standard
- Main reference gauge
- Research
- In-house standard
-
Inficon – Edge CDG025D2
Add to cartAdvantages
- Easy integration, EtherCAT, wide variety of full scales and flanges, standard with two set points
- Easy one push button or remote signal zero command, zero offset adjustable
- Diagnostic port for quick service and maintenance
- Corrosion resistant ceramic sensor
- Excellent long term signal stability
- Temperature compensated
- Sensor protected from contamination
- Compliance & standards: CE, EN, UL, SEMI, RoHS
Typical applications
- Etch, PVD and other semiconductor production processes
- Data storage and display manufacturing equipment
- Industrial vacuum equipment
- General high accuracy pressure measurement
-
Inficon – Edge CDG045D2
Add to cartAdvantages
- Compact, saves valuable tool space
- Easy integration, EtherCAT, wide variety of full scales and flanges, standard with two set points
- Easy one push button or remote signal zero command, zero offset adjustable
- Diagnostic port for quick service and maintenance
- Two year warranty, longer life time with advanced heating concept and gauge protection
- No long term recalibration due to excellent signal stability and repeatability, even in harsh plasma applications
- Compliance & standards: CE, EN, UL, SEMI, RoHS
Typical applications
CVD, Etch, PVD and other semiconductor production processes
-
Inficon – Edge CDG100D2
Add to cartAdvantages
- Compact, saves valuable tool space
- Easy integration, EtherCAT, wide variety of full scales and flanges, standard with two set points
- Easy one push button or remote signal zero command, zero offset adjustable
- Diagnostic port for quick service and maintenance
- Two year warranty, longer life time with advanced heating concept and gauge protection
- No long term recalibration due to excellent signal stability and repeatability, even in harsh plasma applications
- Compliance & standards: CE, EN, UL, SEMI, RoHS
Typical applications
CVD, Etch, PVD and other semiconductor production processes