Only logged in customers who have purchased this product may leave a review.
Inficon – VGC031
Advantages
- Displays and control wide measurement range from 1.3×10-4 up to 1333 mbar
- Bright digital OLED display with keypad for simple set up and Operation
- 4 user selectable analog output signals, 2 set point relays
- RS232/RS485 digital Interface
- Space saving design – 1/8″ DIN panel mount housing for rack mount installation or as standalone unit
- Powered through user supplied 12 to 28 V (dc) or by INFICON’s VGC031 Power Supply
- Compliance & standards: CE, RoHS
- Replacement capability for Granville-Phillips® 375 and 475 controllers and 275 Convectron® gauge sensors and gauge cable (note: remote interface, relay and power connectors are different)
Related products
-
Inficon – PCG55x
Add to cart- Gas type independent above 10 mbar – allows safe venting with any gas mixture
- High accuracy and reproducibility at atmosphere – for reliable, fast atmospheric pressure detection
- Versatile of mounting orientation – provides engineering freedom in tool design
- Available with Tungsten (PCG550) or Nickel (PCG552) filament or with a fully ceramic coated (PCG554) sensor unit for highly corrosive applications
- Latest EtherCAT protocol Standard ETG.5003.2080 S (R) V1.3.0
- Easy to exchange plug & play sensor element with on-board calibration data – guarantees high reproducibility and low cost of ownership
- Selectable output signal for easy integration
- Optional atmospheric switch, display and digital interfaces
- Compliance & standards: CE, EN, UL, CSA, RoHS
-
Inficon – Trigon BCG552
Add to cartAdvantages
- 3 + 1 sensing elements for extremely wide measurement range, cost reduction & space savings
- 2 filaments for Bayard-Alpert system
- Gas type independent pressure measurement above 10 Torr provides more reliable load lock control for any gas mixtures
- Differential pressure measurement eliminates uncertainty related to atmospheric pressure changes
- Automatic high vacuum Pirani adjustment reduces operator interventions
- Galvanic isolated electronics to avoid electric stray current
- Sliding emission mode to avoid pressure jumps and freeze when switching the emission stream
- Set point relays
- Bright & big OLED display (90° rotatable) with user interface
- Analog output, RS232C serial interface, EtherCAT®
- Usable in conjunction with VGC50x Controller series
- Backwards compatible to TripleGauge® BCG450
- RoHS compliance
Typical applications
- Pressure measurement in Semiconductor processes, transfer and loadlock chambers
- Industrial coating
- General vacuum measurement and control on systems in the low to ultra high vacuum range
-
Inficon – PBR 260
Add to cartAdvantages
- PBR 260 Pirani/Bayard-Alpert hot cathode combination gauge offers general vacuum measurement and control in the low to ultrahigh vacuum range with just one compact measuring device
- Flange size: DN 25 ISO-KF, DN 40 CF-R, DN 40 ISO-KF
- Maximum pressure applies to inert gases and temperatures of less then 55°C
- Highly accurate, excellent repeatability in the process range 10-8 … 10-2 mbar
- Bayard-Alpert sensor ON/OFF automatically controlled by Pirani sensor
- Long-life yttrium oxide coated iridium filament
- RoHS compliance
Drop in compatible to other manufacturers PBR 260 Pirani/Bayard-Alpert hot cathode gauges
- Part number IGG27000 matches PT R27 000
- Part number IGG27001 matches PT R27 001
- Part number IGG27002 matches PT R27 00
Typical applications
- General pressure measurement in semiconductor and analytical process environment
- Optical and other industrial coating processes
-
Inficon – Trigon BAG552
Add to cartAdvantages
- Pure Bayard-Alpert measuring system for a wide UHV & HV measurement range
- 2 filaments for Bayard-Alpert system
- Galvanic isolated electronics to avoid electric stray current
- Sliding emission mode to avoid pressure jumps and freeze when switching the emission stream
- Extended bakeability due to removable calibration data chips
- Set point relays
- Bright & big OLED display (90° rotateable) with user interface
- Analog output, RS232C serial interface, EtherCAT®
- Usable in conjunction with VGC50x Controller series
- RoHS compliance
Typical applications
- Pressure measurement in Semiconductor processes
- Industrial coating
- General vacuum measurement and control on systems in the high to ultra high vacuum range
-
Inficon – PGE300
Add to cartAdvantages
- Convection Enhanced Pirani Technology for wide measurement range and higher accuracy near atmosphere
- All-in-One active gauge with built-in display, 1 set point and 3 selectable analog output signals
- Bright digital LED display features a user friendly for calibration and operation
- 3 optional analog output signals (user selectable)
- Factory pre-set analog output signal or selectable via user interface
- Factory pre-set display units or selectable via user interface
- User programmable set point relays
- Gold plated tungsten filament
- Mechanical strength, highly robust and less susceptible to mechanical shock and vibration
- Choice of flange options
- Compliance & standards: CE, RoHS
- Direct drop in replaces most Granville-Phillips® Mini-Convectron® modules (GP275) and ideal device forupgrading your installed thermocouple gauges (Granville-Phillips® and Mini-Convectron® are registered trademarks of MKS Instruments, Andover, MA)
Typical applications
- Fore vacuum pressure measurement
- General vacuum measurement and control from low to the high vacuum range
Reviews