Inficon – VSC150A
Advantages
- High switching accuracy (± 0.1 mbar)
- Stable long term operating characteristics
- Rugged, corrosion protected design
Typical Applications
- Pressure switch or differential pressure switch to control valves, pumps, power supplies
- Load lock chambers
- Process chambers
Related products
-
Inficon – PBR 260
Add to cartAdvantages
- PBR 260 Pirani/Bayard-Alpert hot cathode combination gauge offers general vacuum measurement and control in the low to ultrahigh vacuum range with just one compact measuring device
- Flange size: DN 25 ISO-KF, DN 40 CF-R, DN 40 ISO-KF
- Maximum pressure applies to inert gases and temperatures of less then 55°C
- Highly accurate, excellent repeatability in the process range 10-8 … 10-2 mbar
- Bayard-Alpert sensor ON/OFF automatically controlled by Pirani sensor
- Long-life yttrium oxide coated iridium filament
- RoHS compliance
Drop in compatible to other manufacturers PBR 260 Pirani/Bayard-Alpert hot cathode gauges
- Part number IGG27000 matches PT R27 000
- Part number IGG27001 matches PT R27 001
- Part number IGG27002 matches PT R27 00
Typical applications
- General pressure measurement in semiconductor and analytical process environment
- Optical and other industrial coating processes
-
Inficon – PPG570
Add to cartAdvantages
- Gas type independent above 2 mbar – allows safe venting with any gas mixture
- High accuracy and reproducibility at atmosphere – for reliable, fast atmospheric pressure detection
- Atmospheric ambient pressure measurement
- Up to 3 solid state relays
- Versatile of mounting orientation – provides engineering freedom in tool design
- Selectable analog output signal for easy system integration
- Digital interfaces RS232/ RS485
- Able to direct drop in replace MKS901P “MicroPirani™ – and Piezo Loadlock Vacuum Pressure Transducer”.
- Compliance & standards: CE, EN, UL, CSA, RoHS
Typical applications
- Semiconductor load-lock applications
- Use in Analytical equipment/ mass sepctrometers
- Physical vapor deposition
- Physical vapor deposition
-
Inficon – Trigon BCG552
Add to cartAdvantages
- 3 + 1 sensing elements for extremely wide measurement range, cost reduction & space savings
- 2 filaments for Bayard-Alpert system
- Gas type independent pressure measurement above 10 Torr provides more reliable load lock control for any gas mixtures
- Differential pressure measurement eliminates uncertainty related to atmospheric pressure changes
- Automatic high vacuum Pirani adjustment reduces operator interventions
- Galvanic isolated electronics to avoid electric stray current
- Sliding emission mode to avoid pressure jumps and freeze when switching the emission stream
- Set point relays
- Bright & big OLED display (90° rotatable) with user interface
- Analog output, RS232C serial interface, EtherCAT®
- Usable in conjunction with VGC50x Controller series
- Backwards compatible to TripleGauge® BCG450
- RoHS compliance
Typical applications
- Pressure measurement in Semiconductor processes, transfer and loadlock chambers
- Industrial coating
- General vacuum measurement and control on systems in the low to ultra high vacuum range
-
Inficon – BPG400
Add to cartAdvantages
- Extremely wide measurement range from 5×10-10 mbar to atmosphere (3.8×10-10 Torr to atmosphere)
- Excellent repeatability in the process pressure range from 10-8 … 10-2 mbar of 5%
- The Pirani interlock protects the Bayard-Alpert system from premature filament burnout and excess contamination from high pressure operation
- Long-life yttrium oxide coated iridium filament
- Optional graphic display and Fieldbus interfaces available
- Automatic high vacuum Pirani adjustment reduces operator interventions
- RoHS compliance
- General vacuum measurement and control in the low to ultra high vacuum range
Typical applications
- Pressure measurement in semiconductor process and transfer chambers
- Industrial coating
- General vacuum measurement and control in the low to ultra high vacuum range
-
Inficon – Trigon BPG552
Add to cartAdvantages
- Dual Gauge (2 sensing elements) for a wide measurement range, cost reduction & space savings
- 2 filaments for Bayard-Alpert system
- Pirani interlock protection to avoid premature filament burnout
- Automatic high vacuum Pirani adjustment reduces operator interventions
- Galvanic isolated electronics to avoid electric stray current
- Sliding emission mode to avoid pressure jumps and freeze when switching the emission stream
- Extended bakeability due to removable calibration data chips
- Set point relays
- Bright & big OLED display (90° rotatable) with user interface
- Analog output, RS232C serial interface, EtherCAT®
- Usable in conjunction with VGC50x Controller series
- Backwards compatible to BPG402
- RoHS compliance
Typical applications
- Pressure measurement in Semiconductor processes
- Industrial coating
- General vacuum measurement and control on systems in the low to ultra high vacuum range